Accredited calibration laboratory for gas meters and standards
The inotech calibration laboratory in Bietigheim is accredited by DAkkS to DIN EN ISO/IEC 17025:2018 (D-K-23505-01). We calibrate in the laboratory and at your site – with the same measurement uncertainty.
Calibration and measurement capabilities (CMC)
Extract from the annexes to the accreditation certificate, valid from 12 Aug 2026. All quantities are also accredited for on-site calibration – with identical measurement uncertainty.
Critical flow nozzles and gas meters, in-house methods AA-108.005 to AA-108.007, calibration with atmospheric air. In the laboratory, above 2,650 m³/h only for systems with their own flow generation.
DKD-R 6-1:2014, pressure medium gas.
DKD-R 5-1:2023, comparison with reference thermometer in a liquid bath.
DKD-R 5-8:2019, electrical hygrometers with display in a temperature/humidity generator, medium air at 20 °C to 30 °C. Uncertainty as an absolute value of relative humidity.
Measurement, f = respective measured value.
The current status of the accreditation in the DAkkS database is authoritative: www.dakks.de
What we calibrate
Nozzles, reference and transfer meters from gas meter test systems – regardless of the system manufacturer.
Pressure gauges, resistance thermometers and hygrometers from test systems and production.
Test equipment from meter production and comparison meters for ongoing quality assurance.
A specific measurement uncertainty budget for every test system – regardless of the manufacturer and the installed components.
In the laboratory or at your site
Flow calibration with atmospheric air up to 6,500 m³/h, plus pressure, temperature, humidity and frequency.
The system stays where it is and production keeps running – a unique advantage over suppliers that calibrate only in their own laboratory.
How calibration works
Quantity, measuring range, number of items and preferred location – in the laboratory or on site.
We agree on calibration points and a date and, if required, plan the visit to your system.
According to DKD guidelines and accredited in-house methods, traceable to national standards.
DAkkS calibration certificate with results and expanded measurement uncertainty.
Accreditation D-K-23505-01
DAkkS accreditation of the calibration laboratory of INOTECH Germany GmbH according to DIN EN ISO/IEC 17025. Certificate and annexes available for download in German and English.
DAkkS confirmation: calibration laboratory to DIN EN ISO/IEC 17025:2018, Bietigheim site. Valid from 12 Aug 2026.
Time and frequency: frequency, 0.1 Hz to 100 kHz, also as on-site calibration.
Direct-reading thermometers, relative humidity, pressure and gas flow – each also on site.
Request calibration
Tell us the quantity, measuring range and number of items – we will get back to you with a quotation.
Head of calibration laboratory: Bruno Oster
What our calibration laboratory offers gas meter manufacturers and utilities
When our calibration laboratory calibrates gas meters, critical flow nozzles or transfer meters from your test system, every result can be traced without gaps to national standards. The German Accreditation Body (DAkkS) has accredited the inotech laboratory in Bietigheim (Baden) to DIN EN ISO/IEC 17025:2018. The registration number is D-K-23505-01. Every order ends with a DAkkS calibration certificate stating the measurement results and the expanded measurement uncertainty.
Why do you need this proof? That depends on your role. Meter manufacturers use it to safeguard the factory test equipment and comparison meters against which their production takes its measure every day. If such a reference meter drifts unnoticed, the entire line tests against a shifted yardstick. Utilities with their own verification body base their re-verifications on reliable standards. If your calibration laboratory operates gas meter test lines with its own transfer meters, our results let you prove traceability to auditors.
The references may come from a system we built ourselves, for example a domestic gas meter test system with critical flow nozzles as the standard. Our calibration laboratory equally accepts gas meters from test systems made by other manufacturers. For each test system we also draw up a dedicated measurement uncertainty budget that shows you how much the standards contribute to the overall uncertainty.
On-site calibration with the same measurement uncertainty as in the laboratory
As soon as the standards of a test system are removed and shipped for calibration, the system stands still until everything is back and reinstalled. We therefore also calibrate all accredited quantities on site. The measurement uncertainty with which our calibration laboratory calibrates gas meters and nozzles in your system is the same as in Bietigheim. Shipping and reinstalling the references are no longer necessary, and your production can keep running in the meantime.
Which route pays off depends on size, installation situation and production schedule. For permanently installed nozzles or large reference meters, an on-site appointment is usually the more economical choice. Individual pressure gauges, resistance thermometers or hygrometers, on the other hand, can easily be sent to Bietigheim. Whether the calibration laboratory calibrates gas meters in-house or at your site is clarified as early as the quotation stage.
If you operate several test lines at one site, their calibrations can be bundled into a single visit. Because our calibration laboratory handles gas meters and the associated pressure and temperature sensors in the same appointment, you will see our metrology technicians in your hall less often. This keeps the coordination effort for your maintenance team low.
Gas flow, pressure and temperature within the accredited scope
Atmospheric air serves as the test medium for flow calibration. Volume flows between 2 l/h and 6,500 m³/h are accredited. This range covers domestic meters at minimum load as well as large reference meters. How precisely our calibration laboratory measures gas meters and nozzles is shown by the smallest measurement uncertainty that can be stated (CMC): from 0.2 m³/h it is 0.18 %, and 0.20 % in the range between 16 and 200 l/h. The smaller the uncertainty of the reference, the fewer meters under test fail needlessly just at the limit of the maximum permissible errors.
Rotary piston and turbine gas meters that serve as references in a commercial gas meter test system are also calibrated by us within this range. Up to 6,500 m³/h, the gas meter calibration of your references thus stays with one contact.
Besides the flow reference, every test line includes pressure and temperature measurement. Because our calibration laboratory covers flow, gauge pressure up to 100 bar and temperatures from −40 to 80 °C together, you save separate appointments for the sensors of the same system. We calibrate resistance thermometers with display with a measurement uncertainty of 0.05 K.
Relative humidity between 10 and 90 % and frequencies from 0.1 Hz to 100 kHz round off the scope, for example for hygrometers from production or the measuring equipment used for pulse evaluation.
A calibration laboratory that knows the test system from the inside
Our calibration laboratory is located in the same plant where we design, assemble and test our test systems before delivery. Our metrology technicians therefore know how a nozzle bank is installed and where pressure and temperature are tapped. This knowledge feeds directly into the evaluation of every calibration.
If a deviation is noticed, the question of its cause arises immediately: is it the standard, the installation situation or the evaluation? A calibration laboratory can only assess gas meters in their installed state if it has exactly this knowledge of the system. If the system comes from us, there is no troubleshooting back and forth between system builder and laboratory. Calibration is carried out according to DKD guidelines and accredited in-house procedures.
If you are planning a new meter test system, the initial calibration of its references can be ordered in the same project. The system then starts operation with standards that have already been calibrated under accreditation, provided they fall within our scope.
Regular recalibration via our gas meter calibration service
However stable a standard may seem, it can drift over years of use. We align the interval at which our calibration service recalibrates the gas meters and nozzles of your system with your test task and your quality requirements. This lets you plan calibration dates like maintenance windows instead of having to find a date at short notice when a recalibration falls due.
To prepare a quotation, we only need the measured quantity, measuring range, number of items and the desired location. So that our calibration laboratory can schedule gas meters, nozzles and sensors appropriately, please send these details to calibration@inotech.eu. Bruno Oster, head of our calibration laboratory, will then agree measuring points and the date directly with you. You can reach him by phone on +49 7245 80475-49.