ISO 17025 accredited calibration laboratory +49 7245 80475-0 info@inotech.eu
Home/Products/Commercial gas meter test system

Commercial gas meter test system

Test and calibration systems for diaphragm and rotary piston meters in commercial and light industrial use – as nozzle system or with reference meters, using the same operating concept as the domestic and large gas systems.

Test hall with commercial gas meter test systems
MEASURING RANGE
G10 – G40
FLOW RATE
16 – 65 m³/h
MEASUREMENT UNCERTAINTY
≤ 0.25 %
TEST POSITIONS
1 – 6

What the system delivers

Commercial meters sit between domestic and industrial applications: larger flow rates than G6, but much smaller nominal sizes than large gas meters. The system covers this range with critical-flow nozzles or reference meters – depending on target uncertainty and cycle time.

Clamping, test sequence and reporting are identical to the domestic systems, so operators can switch between systems without retraining. For used meters, a purging function is available to remove residual gases.

Typical operators are meter manufacturers with mixed portfolios, municipal utilities and verification bodies with medium volumes.

Scope of supply

Stainless steel measuring sections with reducers
Reference meter or nozzle bank with pressure and temperature measurement
Hydraulic or pneumatic clamping system
Blower or compressor unit with frequency control
Control cabinet, operator station and test software
Test hall with large gas meter test rigs
TEST HALL WITH MEASURING SECTIONS, BIETIGHEIM PLANT
Shut-off valve of an inotech test system
VALVE OF A STAINLESS STEEL MEASURING SECTION
Nozzle bank with reference nozzles
NOZZLE BANK WITH REFERENCE NOZZLES

For large flow rates and long test cycles

Two reference principles

Reference meters or critical nozzles – combinable for mutual checking during operation.

Stainless steel design

Measuring sections and valves in stainless steel, designed for more than 20 years of use.

Fast meter change

Hydraulic clamping for heavy meters without lifting gear at the test position.

Controlled flow rates

Frequency-controlled blowers for stable test points across the entire measuring range.

Automatic test sequences

Test point sequences, error curves and adjustment values from the test software.

Traceability

References can be recalibrated in the inotech calibration laboratory, DAkkS D-K-23505-01.

Technical specification

VALUES DEPEND ON CONFIGURATION · BINDING IN THE PROJECT DATA SHEET
Measuring range
G10 – G40
Flow rate
16 m³/h to 65 m³/h
Measurement uncertainty
≤ 0.25 %
Test positions
1 to 6
Nominal sizes
DN 40 to DN 80
Reference system
Critical-flow nozzles or reference meters
Test medium
Air, atmospheric operation
Meter types
Diaphragm and rotary piston meters, static meters
Automation
Fully automatic test sequence, optional robot feeding
Software
inotech standard user interface, identical across all system types
Interfaces
ERP/MES integration, network, database and CSV export
Documentation
Test reports, calibration certificates, ISO 17025-capable traceability

Configuration and expansion

High-pressure extension

Configuration as a closed-loop system for natural gas up to 66 bara.

Additional measuring sections

Parallel lines for smaller nominal sizes without modification.

Meter handling

Roller conveyors and lifting aids for heavy meters.

Retrofit

Replacement of controls, reference technology and software on existing systems.

Do you have specific technical requirements?

Send us your specification – meter types, flow ranges, number of test positions and the required degree of automation.